01. ½ºÀ§Ä¡Çãºê
02. ½ºÀ§Ä¡ (PoE)
03. ½ºÀ§Ä¡ (»ê¾÷¿ë)
04. PoEÀÎÁ§ÅÍ/¸®ÇÇÅÍ
05. ±¤(Fiber)
06. ÄÁ¹öÅÍ & ±¤¸ðµâ
07. ¹«¼±AP
08. ¾ÈÅ׳ª/¾Ç¼¼»ç¸®
09. ÀÎÅͳݰøÀ¯±â
10. ¹«¼±·£Ä«µå
11. À¯¼±·£Ä«µå
12. NAS ½ºÅ丮Áö
13. VPN ¹æÈ­º®
14. µ¥ÀÌŸ/Æѽº¸ðµ©
15. ½Ã¸®¾óÅë½Å
16. ÇÁ¸°Åͼ­¹ö
17. KVM ½ºÀ§Ä¡
18. ¿µ»ó/À½Çâ/Åë½Å
19 ºÐ¹è±â/ÁõÆø±â
20. UPS º¸Á¶Àü¿ø
21. CCTV/ipÄ«¸Þ¶ó
22. Çãºê/¼­¹ö RACK
23. ÄÉÀ̺í
24. Á¨´õ
25. ·£°ø»ç ÀÚÀç
26. ±âŸ ÁÖº¯±â±â
27. Àú¿ï
28. ¿Â¶óÀÎ °ßÀû°Ç... (ÃÖÀú°¡ »ó´ã)
ÀÚ·á½Ç
°í°´Áö¿ø ¿¬¶ôó
À¯¿ëÇÑ Á¤º¸
Áú¹®°ú ´ë´ä
»ç¿ëÈı⠸ðÀ½
 TEL : 02-707-3385

  FAX : 02-707-3368

Æò¡¡ÀÏ 10:00 ~ 18:00
Åä¿äÀÏ 10:00 ~ 14:00
°øÈÞÀÏ/ÀÏ¿äÀÏ ÈÞ¹«


À̸ÞÀϹ®ÀÇ
±â¾÷ ÀºÇà
284-074429-01-028
 
 
 
ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â
02. ½ºÀ§Ä¡ (PoE) > ¨ë 24Æ÷Æ® > + 4 SFP > Netgear [GSM7228PS] ProSafe 24-Port Stackable Gigabit PoE Managed ½ºÀ§Ä¡Çãºê (ÃÖ´ë 384Watt Áö¿ø)

 
Netgear [GSM7228PS] ProSafe 24-Port Stackable Gigabit PoE Managed ½ºÀ§Ä¡Çãºê (ÃÖ´ë 384Watt Áö¿ø)
ÆǸŰ¡°Ý : 4,150,000¿ø
¼ö·® EA
 
 
     
 






PHYSICAL INTERFACES


Front


-24 auto-sensing RJ45 10/100/1000 ports


-4 shared SFP ports for Gigabit fi ber uplinks (shared with the last 4 RJ45 ports)


-2 independent 10Gigabit SFP+ ports (accommodate also Gigabit and 100FX SFPs)


-USB port (confi g/fi rmware fi les storage)


 


Rear


-2 additional 10 Gigabit I/O module bays (for 10 Gigabit uplinks or hardware stacking)


-Serial RS-232 port for console


 


Total


-24 x Gigabit ports + 4 x 10 Gigabit ports


-Same hardware platform as GSM7328S-200


 


POE


-All 24 Gigabit RJ45 ports are PoE


-IEEE 802.3af (up to 15.4 Watts/port)


 


POE+


-The first 8 Gigabit RJ45 ports are PoE+


-IEEE 802.3at (up to 30 Watts/port)


 


TOTAL POE BUDGET


-384 Watts


 


PROCESSOR / MEMORY


-Processor: MPC8633 @ 666 MHz


-System memory: 256 MB (RAM)


-Packet buffer memory: 0.75 MB per switch


-Code storage (fl ash): 32 MB


 


HARDWARE STACKING


-GSM7228PS/GSM7252PS


-GSM7328S-200/GSM7352S-200


-GSM7328FS


-Previous GSM7328S/GSM7352S


-Stack height: 8 switches/384 ports


 


PERFORMANCE SUMMARY


-Switching fabric: 144 Gbps


-Throughput: 107.1 Mpps


-Forwarding mode: Store-and-forward


-Latency (64-byte frames, 10 to 100 Mbps): <35.2¥ìs


-Latency (64-byte frames, 1 Gbps): <4.1¥ìs


-Latency (64-byte frames, 10 Gbps): <2.0¥ìs


-Addressing: 48-bit MAC address


-Address database size: 8,000 MAC addresses


-Number of VLANs: 1,024 (IEEE 802.1Q)


-Number of multicast groups fi ltered: 1,024


-Number of trunks: 64 trunks, 8-port per trunk


-Number of hardware queues for QoS: 8


-Number of static routes: 224


-Number of IP interfaces: 128


-Jumbo frame support: up to 9K packet size


-Acoustic noise (ANSI-S10.12): 44 dB @ 25¡ÆC ambient temperature


-Heat dissipation: 260.49 Btu/hr


-Mean time between failures (MTBF): 211,069 hours (~24.1 years) @ 25 ¡ÆC and 98,705 hours (~11.3 years) @ 55 ¡ÆC ambient temperature


 


 


 


 


L3 SERVICES - ROUTING


-L2+ static routing (Subnets, VLANs)


-224 IP routes (L3-capable hardware)


-128 IP interfaces (L3-capable hardware)


-IP Source Guard


 


L3 SERVICES - DHCP


-DHCP server (1,024 clients)


-DHCP L2 relay, DHCP snooping


 


L3 SERVICES - MULTICAST


-IGMP querier


 


L2 SERVICES - SWITCHING


-MAC Address table: 8,000


-ARP cache size: 1,664


-Proxy ARP, Dynamic ARP Inspection


 


L2 SERVICES - VLANS


-IEEE 802.1Q static VLAN (up to 1,024 VLANs)


-IEEE 802.1v Protocol VLAN


-Port-based VLAN


-MAC-based VLAN


-IP subnet-based VLAN


-Protocol-based VLAN


-Voice VLAN (based on IP phones OUIs)


-Guest VLAN with IEEE 802.1x


-Auto VLAN Assignment via RADIUS


-IEEE 802.1 Q-in-Q (Double-VLAN tagging)


-GARP with GVRP/GMRP (automatic registration for membership in VLANs or inmulticast groups)


-Private VLAN groups


 


L2 SERVICES - AVAILABILITY


-IEEE 802.3ad Link Aggregation (Static or LACP) up to 64 trunks per stack and up to 8 ports per trunk


-User selectable LAG hashing algorithm


-IEEE 802.1D Spanning Tree Protocol


-IEEE 802.1w Rapid Spanning Tree


-IEEE 802.1s Multiple Spanning Tree


 


L2 SERVICES - MULTICAST


-IGMP v1, v2, v3 snooping support


-IGMP querier mode support


-Static multicast fi ltering (1,024 multicast groups)


 


L2/L3/L4 SERVICES - QOS


-L2/L3/L4 QoS: MAC, IP, TCP/UDP ports


-IEEE 802.1p Class of Service (CoS)


-DiffServ QoS (RFC 2998)


-Weighted round robin (WRR) queue technology


-Strict priority queue technology


-Ingress rate limit in 1 Kbps increments


-Egress traffi c shaping


 


 


L2/L3/L4 SERVICES - SECURITY


-Access control lists (ACL) L2/L3/L4: MAC, IP, TCP


-MAC-based source/destination ACL


-IP subnet-based source/destination ACL


-Protocol-based source/destination ACL


-ACL over VLAN


-Dynamic ACLs


-1,024 ACLs


-Network storm protection including broadcast multicast and unicast traffic


-DoS


-Protected ports


-Port locking


-MAC filtering/ -Port security/ -DHCP snooping


-IP Source Guard


-Dynamic ARP inspection


-RADIUS (RFC 2865)


-RADIUS accounting (RFC 2866)


-IEEE 802.1x port access authentication (RADIUS)


-Network access control: Captive portal with internal authentication or external RADIUS authentication


-Possible configuration of 10 captive portals


-TACACS+


 


IEEE NETWORK PROTOCOLS


-IEEE 802.3 Ethernet


-IEEE 802.3i 10BASE-T


-IEEE 802.3u 100BASE-T


-IEEE 802.3ab 1000BASE-T


-IEEE 802.3z Gigabit Ethernet 1000BASE-SX/LX


-IEEE 802.3ae 10-Gigabit Ethernet


-IEEE 802.3af Power over Ethernet


-IEEE 802.3at Enhanced Power over Ethernet


-IEEE 802.3ad Trunking (LACP)


-IEEE 802.1AB LLDP with ANSI/TIA-1057 (LLDP-MED)


-IEEE 802.1D Spanning Tree (STP)


-IEEE 802.1s Multiple Spanning Tree (MSTP)


-IEEE 802.1w Rapid Spanning Tree (RSTP)


-IEEE 802.1p Quality of Service


-IEEE 802.1Q VLAN tagging


-IEEE 802.1v protocol-based VLAN


-IEEE 802.1X Radius Network Access Control


-IEEE 802.3x flow control


 


IETF RFC STANDARDS - SYSTEM FACILITIES


-RFC 768 UDP


-RFC 783 TFTP


-RFC 791 IP


-RFC 792 ICMP


-RFC 793 TCP


-RFC 826 Ethernet ARP


-RFC 894 transmission of IP datagrams over Ethernet networks


-RFC 896 congestion control in IP/TCP networks


-RFC 951 BOOTP


-RFC 1321 message-digest algorithm


-RFC 1534 interoperation between BOOTP and DHCP


-RFC 2131 DHCP client/server


-RFC 2132 DHCP options & BOOTP vendor extensions


-RFC 2030 Simple Network Time Protocol (SNTP) version 4 for IPv4, IPv6 and OSI


-RFC 2865 RADIUS Client (both switch and management access)


-RFC 2866 RADIUS Accounting


-RFC 2868 RADIUS attributes for Tunnel Protocol support


-RFC 2869 RADIUS Extensions


-RFC2869bis RADIUS support for Extensible Authentication Protocol (EAP)


-RFC 3164 The BSD Syslog Protocol


-RFC 3580 802.1X RADIUS usage guidelines (VLAN assignment via RADIUS, dynamic VLAN)


 


 


IETF RFC STANDARDS - SWITCHING MIB


-RFC 1213 MIB-II


-RFC 1493 Bridge MIB


-RFC 1643 Ethernet-like MIB


-RFC 2233 The Interfaces Group MIB using SMI v2


-RFC 2674 VLAN MIB


-RFC 2613 SMON MIB


-RFC 2618 RADIUS Authentication Client MIB


-RFC 2620 RADIUS Accounting MIB


-RFC 2737 Entity MIB version 2


-RFC 2819 RMON Groups 1,2,3 & 9


-IEEE 802.1X MIB (IEEE 802.1-PAE-MIB 2004 Revision)


-IEEE 802.1AB - LLDP MIB


-ANSI/TIA 1057 - LLDP-MED MIB


-Private Enterprise MIBs supporting switching features


 


IETF RFC STANDARDS - QOS


-RFC 2474 defi nition of the Differentiated Services Field (DS Field) in the IPv4 and IPv6 headers


-RFC 2475 an architecture for differentiated services


-RFC 2597 Assured Forwarding PHB Group


-RFC 3246 An Expedited Forwarding PHB (Per-Hop Behavior)


-RFC 3260 New Terminology and Clarifi cations for DiffServ


-RFC 3289 - Management Information Base for the Differentiated Services


 


Architecture (read-only)


-Private MIBs for full confi guration of DiffServ, ACL and CoS functionality


 


MANAGEMENT


-SNMP v1, v2c, v3 with multiple IP addresses


-Port mirroring support (many-to-one)


-Flow-based mirroring


-Syslog


-TFTP, SFTP, HTTP, SCP, or local USB fl ash for Confi guration fi les and fi rmware upgrades


-Runtime image download (TFTP)


-Port description


-sFlow¢ç


-Web-based graphic user interface (GUI)


-Command Line interface (CLI)


-IPv6 Management


-Cable Test


-SSLv3/TLSv1.0 Web security for the GUI


-Secure Shell (SSHv1, v2) for CLI


-Telnet sessions for management CPU (5 sessions)


-Confi gurable management VLAN


-Auto Install


-Admin access control via RADIUS or TACACS+


 


LEDS


-Per port: Speed, link, activity


-Per device: Power, fan status, stack ID,


-RPS, master


 


PHYSICAL SPECIFICATIONS


-Dimensions (w x d x h): 440 x 391 x 43 mm (17.3 x 15.4 x 1.7 in)


-Weight: 6.3 kg (13.89 lb)


 


POWER CONSUMPTION


-545W maximum 100-240V AC, 50-60 Hz universal input when PoE output 384W (all ports used)


 


 


IETF RFC STANDARDS - MANAGEMENT


-RFC 854 Telnet


-RFC 855 Telnet Option


-RFC 1155 SMI v1


-RFC 1157 SNMP


-RFC 1212 Concise MIB Defi nitions


-RFC 1867 HTML/2.0 Forms with fi le upload extensions


-RFC 1901 Community-based SNMP v2


-RFC 1908 Coexistence between SNMP v1 & SNMP v2


-RFC 2068 HTTP/1.1 protocol as updated by draft-ietf-http-v11-spec-rev-03


-RFC 2271 SNMP Framework MIB


-RFC 2295 Transparent Content Negotiation


-RFC 2296 Remote Variant Selection; RSVA/1.0 State Management ¡°cookies¡± - draft-ietf-http-state-mgmt-05


-RFC 2576 Coexistence between SNMP v1, v2 and v3


-RFC 2578 SMI v2


-RFC 2579 Textual Conventions for SMI v2


-RFC 2580 Conformance statements for SMI v2


-RFC 3410 Introduction and Applicability Statements for Internet Standard


 


Management Framework


-RFC 3411 An Architecture for Describing SNMP Management Frameworks


-RFC 3412 Message Processing & Dispatching


-RFC 3413 SNMP Applications


-RFC 3414 User-based Security Model


-RFC 3415 View-based Access Control Model


-RFC 3416 Version 2 of SNMP Protocol Operations


-RFC 3417 Transport Mappings


-RFC 3418 Management Information Base(MIB) for the Simple Network


 


Management Protocol (SNMP)


-SSL 3.0 and TLS 1.0


 ¡Ü RFC 2246 The TLS Protocol, Version 1.0


 ¡Ü  RFC 2818 HTTP over TLS


 ¡Ü RFC 2346 AES Ciphersuites for Transport Layer Security


-SSH 1.5 and 2.0


 ¡Ü RFC 4253 SSH Transport Layer Protocol


 ¡Ü RFC 4252 SSH Authentication Protocol


 ¡Ü RFC 4254 SSH Connection Protocol


 ¡Ü RFC 4251 SSH Protocol Architecture


 ¡Ü RFC 4716 SECSH Public Key File Format


 ¡Ü RFC 4419 Diffi e-Hellman Group Exchange for the SSH


 ¡Ü ransport Layer Protocol


 


ENVIRONMENTAL SPECIFICATIONS


Operating:


-temperature: 32¡Æ to 122¡ÆF (0¡Æ to 50¡ÆC)


-humidity: 90% maximum relative humidity, non-condensing


-altitude: 10,000 ft (3,000 m) maximum


Storage:


-temperature: - 4¡Æ to 158¡ÆF (-20¡Æ to 70¡ÆC)


-humidity: 95% maximum relative humidity, non-condensing


-altitude: 10,000 ft (3,000 m) maximum


 


ELECTROMAGNETIC EMISSIONS AND IMMUNITY


-CE mark, commercial


-FCC Part 15 Class A, VCCI Class A


-Class A EN 55022 (CISPR 22) Class A


-Class A C-Tick


-EN 50082-1


-EN 55024


 


SAFETY


-CE mark, commercial


-CSA certifi ed (CSA 22.2 #950)


-UL listed (UL 1950)/cUL IEC 950/EN 60950


 


PACKAGE CONTENT


-ProSafe¢ç 24-port Stackable, Gigabit PoE L2+ Managed Switch (GSM7228PS)


-Power cord


-Rubber footpads for tabletop installation


-Rubber caps for the SFP and SFP+ sockets


-Rack-mounting kit


-Null-modem serial cable (RS-232) with 9-pin connector


-Resource CD


-ProSafe NMS100 Network Management System 30-day trial CD-ROM


 


WARRANTY


-ProSafe Lifetime Warranty


 


MODULES


-AGM731F 1000BASE-SX SFP GBIC


-AGM732F 1000BASE-LX SFP GBIC


-AXM761 10GBASE-SR SFP+ GBIC


-AXM762 10GBASE-LR SFP+ GBIC


-AX742 24Gigabit Stacking Kit


-AX743 10Gigabit SFP+ Adapter Module


-AX744 10Gigabit CX4 Module


-APS525W Power Supply Spare Module


 


ORDERING INFORMATION


Americas


-GSM7228PS-100NAS


Europe, Korea


-GSM7228PS-100EUS


Asia


-GSM7228PS-100AJS


 


PROSUPPORT SERVICE PACKS


-OnCall 24x7, Category 3: PMB0333


-XPressHW, Category 3: PRR0333-100

 
¡Ú ¹è¼Û±â°£ ¡Ú
ÀÔ±Ý È®ÀÎÈÄ Æò±Õ 3ÀÏ À̳»·Î ¹è¼ÛµË´Ï´Ù. Åä¿äÀÏ/°øÈÞÀÏÀº ¹è¼Û±â°£¿¡ Æ÷ÇÔµÇÁö ¾Ê½À´Ï´Ù.
ÀϹÝÀûÀ¸·Î ÆòÀÏÀº ´çÀÏ ¿ÀÈÄ4½Ã 30ºÐ Àü±îÁö,Åä¿äÀÏÀº ´çÀÏ ¿ÀÈÄ 1½Ã±îÁö ÀÔ±ÝÈ®ÀÎÀÌ µÇ¸é ´ÙÀ½ ³¯ ¹Þ¾Æº¸½Ç ¼ö ÀÖ½À´Ï´Ù.
´Ü, µµ¼­/»ê°£Áö¿ªÀº 2¡­3ÀÏ Á¤µµ Ãß°¡ ¼Ò¿äµË´Ï´Ù.
ºÒ°¡Ç×·ÂÀû(ÀϽÃÇ°Àý, Á¦Á¶»ç »óÇ°¼ö±Þ ¹®Á¦, õÀçÁöº¯ µî)ÀÎ »çÀ¯·Î ¹è¼ÛÀÌ ´Ê¾îÁú¼ö ÀÖ½À´Ï´Ù.

¡Ú ¹è¼ÛÁö¿ª ¡Ú
Àü±¹ (ÀϺÎÁö¿ª Á¦¿Ü)

¡Ú ¹è¼Ûºñ ¡Ú
1¹Ú½º´ç 2500¿ø(Åùè) (µµ¼­ »ê°£Áö¿ªÀº Ãß°¡ºñ¿ë ÀÖÀ»¼ö ÀÖ½À´Ï´Ù.)
ºÎÇdzª Áß·®ÀÌ Å« Á¦Ç°Àº ¹è¼Û ¹æ¹ýÀÌ º¯°æ µÉ ¼ö ÀÖÀ¸¸ç ÀÌ¿¡ µû¸¥ ¿îÀÓºñ°¡ Ãß°¡ µÉ ¼ö ÀÖ½À´Ï´Ù.
¹è¼ÛÀÌ ´Ê¾îÁö´Â °æ¿ì ¹Ì¸® ¿¬¶ôµå¸³´Ï´Ù.
°¢ Á¦Á¶»çÀÇ A/S ±ÔÁ¤¿¡ µû¸¨´Ï´Ù.
Á¦Ç° ±¸¸Å Àμö ÈÄ 7ÀÏ À̳»ÀÇ Á¦Ç°Àº Ãʱ⠺ҷ®¿¡ ÇÑÇØ 1:1 »óÇ° ±³È¯ ¶Ç´Â ȯºÒÀÌ °¡´ÉÇÕ´Ï´Ù.
´Ü, Á¦Ç°ÀÇ ¹Ú½º ¹× ±¸¼º¹°ÀÌ Á¤»ó »óÅ¿¡¼­¸¸ °¡´É ÇÕ´Ï´Ù.
°³ºÀÀ» ¾ÈÇϽŠÁ¦Ç°Áß º¯½É¿¡ ÀÇÇÑ ¹ÝÇ°µµ 7ÀÏ À̳»¿¡¸¸ °¡´ÉÇÕ´Ï´Ù.
Á¦Ç°À» ȯºÒ¹ÞÀ¸½Ã±â À§Çؼ­´Â Á¦Ç°ÀÇ Æ÷Àå»óÅÂ¿Í ³»¿ë¹°ÀÌ ÈѼյÇÁö ¾Ê¾Æ¾ß ÇÏ¸ç ½ºÆ¼Ä¿, Å×ÀÌÇÁ¸¦ ºÙ¿©¼­ Á¦Ç°ÀÇ ¹Ú½º Æ÷ÀåÀÌ ÈѼյǸé ȯºÒÀÌ ºÒ°¡ÇÕ´Ï´Ù.

ÀüÈ­¿¬¶ôÀ» ¸ÕÀú ÁÖ½Ã¸é ½Å¼ÓÇÑ Ã³¸®°¡ µË´Ï´Ù.
 
 
À̸§ : ÷ºÎ : ÆÄÀÏ÷ºÎ
³»¿ë :
ÆòÁ¡
°í°´Æò°¡ : ÆòÁ¡ ¡Ú¡Ú¡Ú¡Ú¡Ú  
 
 
 
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Á¶È¸
 
 
 
»óÈ£¸í : (ÁÖ)¾ÆÀÌÇǵ帲 »ç¾÷ÀÚµî·Ï¹øÈ£ : 581-86-00309 581-86-00309 Åë½ÅÆǸž÷½Å°í¹øÈ£ : Á¦2016-¼­¿ï¿ë»ê-00683È£
[ÀÌ¿ë¾à°ü] [°³ÀÎÁ¤º¸ Ãë±Þ¹æħ] °³ÀÎÁ¤º¸´ã´çÀÚ : ¾È±â¼¼ ´ëÇ¥ : ¾È±â¼¼
»ç¾÷Àå¼ÒÀçÁö : ¼­¿ï ¿ë»ê±¸ »õâ·Î 181 (ÇÑ°­·Î2°¡, ¼±Àλó°¡22µ¿ 1046È£,1047È£,1048È£)
Copyright ¨Ï ·£°ø»ç All Rights Reserved. TEL : 02-707-3385, FAX : 02-707-3368