01. ½ºÀ§Ä¡Çãºê
02. ½ºÀ§Ä¡ (PoE)
03. ½ºÀ§Ä¡ (»ê¾÷¿ë)
04. PoEÀÎÁ§ÅÍ/¸®ÇÇÅÍ
05. ±¤(Fiber)
06. ÄÁ¹öÅÍ & ±¤¸ðµâ
07. ¹«¼±AP
08. ¾ÈÅ׳ª/¾Ç¼¼»ç¸®
09. ÀÎÅͳݰøÀ¯±â
10. ¹«¼±·£Ä«µå
11. À¯¼±·£Ä«µå
12. NAS ½ºÅ丮Áö
13. VPN ¹æÈ­º®
14. µ¥ÀÌŸ/Æѽº¸ðµ©
15. ½Ã¸®¾óÅë½Å
16. ÇÁ¸°Åͼ­¹ö
17. KVM ½ºÀ§Ä¡
18. ¿µ»ó/À½Çâ/Åë½Å
19 ºÐ¹è±â/ÁõÆø±â
20. UPS º¸Á¶Àü¿ø
21. CCTV/ipÄ«¸Þ¶ó
22. Çãºê/¼­¹ö RACK
23. ÄÉÀ̺í
24. Á¨´õ
25. ·£°ø»ç ÀÚÀç
26. ±âŸ ÁÖº¯±â±â
27. Àú¿ï
28. ¿Â¶óÀÎ °ßÀû°Ç... (ÃÖÀú°¡ »ó´ã)
ÀÚ·á½Ç
°í°´Áö¿ø ¿¬¶ôó
À¯¿ëÇÑ Á¤º¸
Áú¹®°ú ´ë´ä
»ç¿ëÈı⠸ðÀ½
 TEL : 02-707-3385

  FAX : 02-707-3368

Æò¡¡ÀÏ 10:00 ~ 18:00
Åä¿äÀÏ 10:00 ~ 14:00
°øÈÞÀÏ/ÀÏ¿äÀÏ ÈÞ¹«


À̸ÞÀϹ®ÀÇ
±â¾÷ ÀºÇà
284-074429-01-028
 
 
 
ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â
06. ÄÁ¹öÅÍ & ±¤¸ðµâ > ¨é ±¤ ¸ðµâ > Cisco > Cisco [GLC-LH-SM] 1000BASE-LX/LH long-wavelength/long haul; without DOM

 
Cisco [GLC-LH-SM] 1000BASE-LX/LH long-wavelength/long haul; without DOM
ÆǸŰ¡°Ý : 643,000¿ø
¼ö·® EA
 
 
     
 

Cisco Transceiver Modules

Cisco SFP Optics For Gigabit Ethernet Applications

The industry-standard Cisco¢ç Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output device that plugs into a Gigabit Ethernet port or slot, linking the port with the network (Figures 1 and 2). SFPs can be used and interchanged on a wide variety of Cisco products and can be intermixed in combinations of 1000BASE-T, 1000BASE-SX, 1000BASE-LX/LH, 1000BASE-EX, 1000BASE-ZX, or 1000BASE-BX10-D/U on a port-by-port basis.

1000BASE-T SFP for Copper networks
The 1000BASE-T SFP operates on standard Category 5 unshielded twisted pair copper cabling of up to 100m (328 ft) link length. Cisco 1000BASE-T SFP modules support 10/100/1000 autonegotiation and Auto MDI/MDIX.

1000BASE-SX SFP for Multimode Fiber Only

The 1000BASE-SX SFP, compatible with the IEEE 802.3z 1000BASE-SX standard, operates on legacy 50 ¥ìm multimode fiber links up to 550 m and on 62.5 ¥ìm Fiber Distributed Data Interface (FDDI)-grade multimode fibers up to 220 m. It can support up to 1km over laser-optimized 50 ¥ìm multimode fiber cable.

1000BASE-LX/LH SFP for Both Multimode and Single-Mode Fibers

The 1000BASE-LX/LH SFP, compatible with the IEEE 802.3z 1000BASE-LX standard, operates on standard single-mode fiber-optic link spans of up to 10 km and up to 550 m on any multimode fibers. When used over legacy multimode fiber type, the transmitter should be coupled through a mode conditioning patch cable. For details on this implementation, refer to http://www.cisco.com/en/US/prod/collateral/modules/ps5455/product_bulletin_c25-530836.html.

1000BASE-EX SFP for Long-Reach Single-Mode Fibers

The 1000BASE-EX SFP operates on standard single-mode fiber-optic link spans of up to 40 km in length. A 5-dB inline optical attenuator should be inserted between the fiber-optic cable and the receiving port on the SFP at each end of the link for back-to-back connectivity.

1000BASE-ZX SFP for Long-Reach Single-Mode Fibers

The 1000BASE-ZX SFP operates on standard single-mode fiber-optic link spans of up to approximately 70 km in length. The SFP provides an optical link budget of 23 dB, but the precise link span length depends on multiple factors such as fiber quality, number of splices, and connectors.
When shorter distances of single-mode fiber (SMF) are used, it might be necessary to insert an inline optical attenuator in the link to avoid overloading the receiver. A 10-dB inline optical attenuator should be inserted between the fiber-optic cable plant and the receiving port on the SFP at each end of the link whenever the fiber-optic cable span loss is less than 8 dB.

1000BASE-BX10-D and 1000BASE-BX10-U SFP for Single-Fiber Bidirectional Applications

The 1000BASE-BX-D and 1000BASE-BX-U SFPs, compatible with the IEEE 802.3ah 1000BASE-BX10-D and 1000BASE-BX10-U standards, operate on a single strand of standard SMF.
A 1000BASE-BX10-D device is always connected to a 1000BASE-BX10-U device with a single strand of standard SMF with an operating transmission range up to 10 km.
The communication over a single strand of fiber is achieved by separating the transmission wavelength of the two devices as depicted in Figure 3: 1000BASE-BX10-D transmits a 1490-nm channel and receives a 1310-nm signal, whereas 1000BASE-BX10-U transmits at a 1310-nm wavelength and receives a 1490-nm signal. Note in Figure 3 the presence of a wavelength-division multiplexing (WDM) splitter integrated into the SFP to split the 1310-nm and 1490-nm light paths.
 
The GLC-BX-D and GLC-BX-U SFPs also support digital optical monitoring (DOM) functions according to the industry-standard SFF-8724 multisource agreement (MSA). This feature gives the end user the ability to monitor real-time parameters of the SFP, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage.

Technical Specifications

Platform Support

The Cisco SFPs are supported across a variety of Cisco switches, routers, and optical transport devices. For more details, refer to the document SFP Compatibility Matrix at http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/compatibility/matrix/OL_6981.pdf.

Connectors and Cabling

Connectors include the following:

• Dual LC/PC connector (1000BASE-SX, 1000BASE-LX/LH, and 1000BASE-ZX)

• Single LC/PC connector (1000BASE-BX-D and 1000BASE-BX-U)

• RJ-45 connector (1000BASE-T)

Note: Only connections with patch cords with PC or UPC connectors are supported. Patch cords with APC connectors are not supported. All cables and cable assemblies used must be compliant with the standards specified in the standards section.

Table 1 provides cabling specifications for the SFPs that you install in the Gigabit Ethernet port. Note that all SFP ports have LC-type connectors, and the minimum cable distance for all SFPs listed (multimode and single-mode fiber) is 6.5 feet (2 m).

Table 1. SFP Port Cabling Specifications

Product

Wavelength (nm)

Fiber Type

Core Size (¥ìm)

Modal Bandwidth (MHz* Km)

Operating Distance (m)

1000BASE-SX

850

MMF

62.5

160

220 (722 ft)

     

62.5

200

275 (902 ft)

     

50

400

500 (1,640 ft)

     

50

500

550 (1,804 ft)

     

50

2000

1000 (3281 ft)

1000BASE-LX/LH

1310

MMF*

62.5

500

550 (1,804 ft)

     

50

400

550 (1,804 ft)

     

50

500

550 (1,804 ft)

   

SMF

-**

-

10,000 (32,821 ft)

1000BASE-EX

1310

SMF

-**

-

40,000 (131,234 ft)

1000BASE-ZX

1550

SMF

-

-

Approximately 70 km depending on link loss

1000BASE-BX-U

1310

SMF

-**

-

10,000 (32,821 ft)

1000BASE-BS-D

1490

SMF

-**

-

10,000 (32,821 ft)

*A mode-conditioning patch cord, as specified by the IEEE standard, is required regardless of the span length. Note how the mode conditioning patch cord for 62.5-¥ìm fibers has a different specification from the mode-conditioning patch cord for 50-¥ìm fibers.

**ITU-T G.652 SMF as specified by the IEEE 802.3z standard.

Optical Specifications

Table 2 gives optical parameters for the SFPs.

Table 2. Main Optical Parameters

Product

Transmit Power (dBm)

Receive Power Range (dBm)

1000BASE-SX

-3 to -9.5

0 to -17

1000BASE-LX/LH

-3 to -9.5

-3 to -20

1000BASE-EX

+3 to -1

+1 to -22

1000BASE-ZX

+5 to 0

-3 to -23

1000BASE-BX10-D

1000BASE-BX10-U

-3 to -9

-3 to -19.5

Dimensions

Dimensions (H x W x D): 8.5 x 13.4 x 56.5 mm. Cisco SFPs typically weigh 75 grams or less.

Environmental Conditions and Power Requirements

Operating temperature range:

• Commercial temperature range (COM): 0 to 70¡ÆC (32 to 158¡ÆF)

• Extended temperature range (EXT): -5¡ÆC to 85¡ÆC (23 to 185¡ÆF)

• Industrial temperature range (IND): -40 to 85¡ÆC (-40 to 185¡ÆF)

• Storage temperature range: -40 to 85¡ÆC (-40 to 185¡ÆF)

Table 3 gives electrical parameters and Table 4 gives temperature range and DOM support information for the SFPs.

Table 3. Electrical Parameters

Parameter

Symbol

Minimum

Typical

Maximum

Units

Supply Current

Is

-

200

300

mA

Surge Current

ISurge

-

-

30

mA

Input Voltage

Vcc

3.1

3.3

3.5

V

Table 4. Temperature Range and DOM Support

Product Number

Temperature Range

DOM

GLC-SX-MM

COM

No

GLC-LH-SM

COM

No

GLC-ZX-SM

COM

Yes

GLC-BX-U

COM

Yes

GLC-BX-D

COM

Yes

GLC-T

COM

n/a

SFP-GE-T

EXT

n/a

SFP-GE-S

EXT

Yes

SFP-GE-L

EXT

Yes

GLC-EX-SMD

EXT

Yes

SFP-GE-Z

EXT

Yes

GLC-SX-MM-RGD

IND

No

GLC-LX-SM-RGD

IND

No

GLC-ZX-SM-RGD

IND

No

Warranty

• Standard warranty: 90 days.

• Extended warranty (option): Available under a Cisco SMARTnet¢ç Service support contract for the Cisco switch or router chassis.

Regulatory and Standards Compliance

Safety:

• Laser Class I 21CFR1040 LN#50 7/2001

• Laser Class I IEC 60825-1

Standards:

• IEEE 802.3z

• IEEE 802.3ah

GR-20-CORE: Generic Requirements for Optical Fiber and Optical Fiber Cable
GR-326-CORE: Generic Requirements for Single-Mode Optical Connectors and Jumper Assemblies
GR-1435-CORE: Generic Requirements for Multifiber Optical Connectors

Ordering Information

To place an order, visit the Cisco Ordering homepage or refer to Table 5.

Table 5. Ordering Information

Product Description

Product Number

1000BASE-T standard

GLC-T

1000BASE-SX short wavelength; without DOM

GLC-SX-MM

1000BASE-LX/LH long-wavelength/long haul; without DOM

GLC-LH-SM

1000BASE-ZX extended distance;

GLC-ZX-SM

1000BASE-BX10-D downstream bidirectional single fiber; with DOM

GLC-BX-D

1000BASE-BX10-U upstream bidirectional single fiber; with DOM

GLC-BX-U

1000BASE-T NEBS 3 ESD

SFP-GE-T

1000BASE-SX short wavelength; with DOM

SFP-GE-S

1000BASE-LX/LH long-wavelength; with DOM

SFP-GE-L

1000BASE-EX long-wavelength; with DOM

GLC-EX-SMD

1000BASE-ZX extended distance; with DOM

SFP-GE-Z

1000BASE-SX short wavelength; rugged

GLC-SX-MM-RGD

1000BASE-LX/LH long wavelength; rugged

GLC-LX-SM-RGD

1000BASE-ZX extended distance; rugged

GLC-ZX-SM-RGD

 
¡Ú ¹è¼Û±â°£ ¡Ú
ÀÔ±Ý È®ÀÎÈÄ Æò±Õ 3ÀÏ À̳»·Î ¹è¼ÛµË´Ï´Ù. Åä¿äÀÏ/°øÈÞÀÏÀº ¹è¼Û±â°£¿¡ Æ÷ÇÔµÇÁö ¾Ê½À´Ï´Ù.
ÀϹÝÀûÀ¸·Î ÆòÀÏÀº ´çÀÏ ¿ÀÈÄ4½Ã 30ºÐ Àü±îÁö,Åä¿äÀÏÀº ´çÀÏ ¿ÀÈÄ 1½Ã±îÁö ÀÔ±ÝÈ®ÀÎÀÌ µÇ¸é ´ÙÀ½ ³¯ ¹Þ¾Æº¸½Ç ¼ö ÀÖ½À´Ï´Ù.
´Ü, µµ¼­/»ê°£Áö¿ªÀº 2¡­3ÀÏ Á¤µµ Ãß°¡ ¼Ò¿äµË´Ï´Ù.
ºÒ°¡Ç×·ÂÀû(ÀϽÃÇ°Àý, Á¦Á¶»ç »óÇ°¼ö±Þ ¹®Á¦, õÀçÁöº¯ µî)ÀÎ »çÀ¯·Î ¹è¼ÛÀÌ ´Ê¾îÁú¼ö ÀÖ½À´Ï´Ù.

¡Ú ¹è¼ÛÁö¿ª ¡Ú
Àü±¹ (ÀϺÎÁö¿ª Á¦¿Ü)

¡Ú ¹è¼Ûºñ ¡Ú
1¹Ú½º´ç 2500¿ø(Åùè) (µµ¼­ »ê°£Áö¿ªÀº Ãß°¡ºñ¿ë ÀÖÀ»¼ö ÀÖ½À´Ï´Ù.)
ºÎÇdzª Áß·®ÀÌ Å« Á¦Ç°Àº ¹è¼Û ¹æ¹ýÀÌ º¯°æ µÉ ¼ö ÀÖÀ¸¸ç ÀÌ¿¡ µû¸¥ ¿îÀÓºñ°¡ Ãß°¡ µÉ ¼ö ÀÖ½À´Ï´Ù.
¹è¼ÛÀÌ ´Ê¾îÁö´Â °æ¿ì ¹Ì¸® ¿¬¶ôµå¸³´Ï´Ù.
°¢ Á¦Á¶»çÀÇ A/S ±ÔÁ¤¿¡ µû¸¨´Ï´Ù.
Á¦Ç° ±¸¸Å Àμö ÈÄ 7ÀÏ À̳»ÀÇ Á¦Ç°Àº Ãʱ⠺ҷ®¿¡ ÇÑÇØ 1:1 »óÇ° ±³È¯ ¶Ç´Â ȯºÒÀÌ °¡´ÉÇÕ´Ï´Ù.
´Ü, Á¦Ç°ÀÇ ¹Ú½º ¹× ±¸¼º¹°ÀÌ Á¤»ó »óÅ¿¡¼­¸¸ °¡´É ÇÕ´Ï´Ù.
°³ºÀÀ» ¾ÈÇϽŠÁ¦Ç°Áß º¯½É¿¡ ÀÇÇÑ ¹ÝÇ°µµ 7ÀÏ À̳»¿¡¸¸ °¡´ÉÇÕ´Ï´Ù.
Á¦Ç°À» ȯºÒ¹ÞÀ¸½Ã±â À§Çؼ­´Â Á¦Ç°ÀÇ Æ÷Àå»óÅÂ¿Í ³»¿ë¹°ÀÌ ÈѼյÇÁö ¾Ê¾Æ¾ß ÇÏ¸ç ½ºÆ¼Ä¿, Å×ÀÌÇÁ¸¦ ºÙ¿©¼­ Á¦Ç°ÀÇ ¹Ú½º Æ÷ÀåÀÌ ÈѼյǸé ȯºÒÀÌ ºÒ°¡ÇÕ´Ï´Ù.

ÀüÈ­¿¬¶ôÀ» ¸ÕÀú ÁÖ½Ã¸é ½Å¼ÓÇÑ Ã³¸®°¡ µË´Ï´Ù.
 
 
À̸§ : ÷ºÎ : ÆÄÀÏ÷ºÎ
³»¿ë :
ÆòÁ¡
°í°´Æò°¡ : ÆòÁ¡ ¡Ú¡Ú¡Ú¡Ú¡Ú  
 
 
 
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Á¶È¸
 
 
 
»óÈ£¸í : (ÁÖ)¾ÆÀÌÇǵ帲 »ç¾÷ÀÚµî·Ï¹øÈ£ : 581-86-00309 581-86-00309 Åë½ÅÆǸž÷½Å°í¹øÈ£ : Á¦2016-¼­¿ï¿ë»ê-00683È£
[ÀÌ¿ë¾à°ü] [°³ÀÎÁ¤º¸ Ãë±Þ¹æħ] °³ÀÎÁ¤º¸´ã´çÀÚ : ¾È±â¼¼ ´ëÇ¥ : ¾È±â¼¼
»ç¾÷Àå¼ÒÀçÁö : ¼­¿ï ¿ë»ê±¸ »õâ·Î 181 (ÇÑ°­·Î2°¡, ¼±Àλó°¡22µ¿ 1046È£,1047È£,1048È£)
Copyright ¨Ï ·£°ø»ç All Rights Reserved. TEL : 02-707-3385, FAX : 02-707-3368