01. ½ºÀ§Ä¡Çãºê
02. ½ºÀ§Ä¡ (PoE)
03. ½ºÀ§Ä¡ (»ê¾÷¿ë)
04. PoEÀÎÁ§ÅÍ/¸®ÇÇÅÍ
05. ±¤(Fiber)
06. ÄÁ¹öÅÍ & ±¤¸ðµâ
07. ¹«¼±AP
08. ¾ÈÅ׳ª/¾Ç¼¼»ç¸®
09. ÀÎÅͳݰøÀ¯±â
10. ¹«¼±·£Ä«µå
11. À¯¼±·£Ä«µå
12. NAS ½ºÅ丮Áö
13. VPN ¹æÈ­º®
14. µ¥ÀÌŸ/Æѽº¸ðµ©
15. ½Ã¸®¾óÅë½Å
16. ÇÁ¸°Åͼ­¹ö
17. KVM ½ºÀ§Ä¡
18. ¿µ»ó/À½Çâ/Åë½Å
19 ºÐ¹è±â/ÁõÆø±â
20. UPS º¸Á¶Àü¿ø
21. CCTV/ipÄ«¸Þ¶ó
22. Çãºê/¼­¹ö RACK
23. ÄÉÀ̺í
24. Á¨´õ
25. ·£°ø»ç ÀÚÀç
26. ±âŸ ÁÖº¯±â±â
27. Àú¿ï
28. ¿Â¶óÀÎ °ßÀû°Ç... (ÃÖÀú°¡ »ó´ã)
ÀÚ·á½Ç
°í°´Áö¿ø ¿¬¶ôó
À¯¿ëÇÑ Á¤º¸
Áú¹®°ú ´ë´ä
»ç¿ëÈı⠸ðÀ½
 TEL : 02-707-3385

  FAX : 02-707-3368

Æò¡¡ÀÏ 10:00 ~ 18:00
Åä¿äÀÏ 10:00 ~ 14:00
°øÈÞÀÏ/ÀÏ¿äÀÏ ÈÞ¹«


À̸ÞÀϹ®ÀÇ
±â¾÷ ÀºÇà
284-074429-01-028
 
 
 
ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â
02. ½ºÀ§Ä¡ (PoE) > ¨ë 24Æ÷Æ® > + 2 SFP > HP ProCurve Switch 2610-24/12PWR (J9086A)

 
HP ProCurve Switch 2610-24/12PWR (J9086A)
ÆǸŰ¡°Ý : 3,360,000¿ø
¼ö·® EA
 
 
     
 

 

Model specifications

Product overview



  • Access layer cost-effective switch
  • Layer 2 plus Static IP Routing
  • Scalable 10/100 connectivity
  • Gigabit fiber uplinks
  • Enterprise-class features

For as long as you own the product, with next-business-day advance replacement (available in most countries). The following hardware products have a five-year hardware warranty for the disk drive and lifetime hardware warranty (for as long as you own the product) for the rest of the module: HP ProCurve ONE Services zl Module, HP ProCurve Threat Management Services zl Module, and HP ProCurve MSM765zl Mobility Controller. The following hardware products and their related series modules have a one-year hardware warranty with extensions available: HP ProCurve Routing Switch 9300m series, HP ProCurve Switch 8100fl series, HP ProCurve Network Access Controller 800, and HP ProCurve DCM Controller. The following hardware products have a one-year hardware warranty with extensions available: HP ProCurve M111 Client Bridge, HP ProCurve MSM3xx-R Access Points, HP ProCurve MSM7xx Mobility and Access Controllers, HP ProCurve RF Manager IDS/IPS Systems, HP ProCurve MSM Power Supplies, HP ProCurve 1-Port Power Injector, HP ProCurve CNMS Appliances, and HP ProCurve MSM317 Access Device. Standalone software, upgrades, or licenses may have a different warranty duration. For details, refer to the ProCurve Software License, Warranty, and Support booklet at www.procurve.com/warranty.

Industry-leading warranty

  • Lifetime Warranty: for as long as you own the product, with next-business-day advance replacement (available in most countries)

Connectivity

  • IEEE 802.3af Power over Ethernet: provides up to 15.4 W per port to IEEE 802.3af-compliant PoE powered devices such as IP phones, wireless access points, and security cameras

  • Pre-standard PoE support: detects and provides power to pre-standard PoE devices; see list of supported devices in the product FAQ at www.ProCurve.com

  • Gigabit Uplink Connectivity: two 10/100/1000BASE-T ports and two mini-GBIC ports for connectivity such as Gigabit (SX, LX, LH, 1000BaseT) and 100Base-FX

  • ProCurve Auto-MDIX: automatically adjusts for straight-through or crossover cables on all 10/100 ports

  • Jumbo packet support: supports up to 9,216 byte frame size to improve performance of large data transfers

Resiliency and high availability

  • IEEE 802.3ad Link Aggregation Protocol (LACP) and ProCurve trunking: support up to 24 trunks, each with up to 8 links (ports) per trunk

  • IEEE 802.1s Multiple Spanning Tree: provides high link availability in multiple VLAN environments by allowing multiple spanning trees; provides legacy support for IEEE 802.1d and IEEE 802.1w

  • Optional redundant power supply: provides uninterrupted power (provided by HP ProCurve 600 RPS/EPS)

Manageability

  • RMON, XRMON, and sFlow: provide advanced monitoring and reporting capabilities for statistics, history, alarms, and events

  • Uni-Directional Link Detection (UDLD): monitors a link between two switches and blocks the ports on both ends of the link if the link goes down at any point between the two devices

  • Command authorization: leverages RADIUS to link a custom list of CLI commands to individual network administrator's login; also provides an audit trail

  • Multiple configuration files: allow multiple configuration files to be stored to flash image

  • Dual flash images: provides independent primary and secondary operating system files for backup while upgrading

  • Stacking capability: single IP address management for a virtual stack of up to 16 switches, including the HP ProCurve Switch 2500 Series, 2510 Series, 2600 Series, 2610 Series, 2810 Series, 2900 Series, 3400cl Series, 3500l Series, 4200vl Series, 6108, 6200yl-24G-mGBIC, and 6400cl Series

  • Friendly port names: allow assignment of descriptive names to ports

  • Find-Fix-Inform: finds and fixes common network problems automatically, then informs administrator

  • Software updates: free downloads from the Web

  • Troubleshooting: ingress and egress port monitoring enable network problem solving

Layer 2 switching

  • VLAN support and tagging: supports the IEEE 802.1Q (4,094 VLAN IDs) and 256 VLANs simultaneously

  • GARP VLAN Registration Protocol: allows automatic learning and dynamic assignment of VLANs

  • IEEE 802.1v protocol VLANs: isolate select non-IPv4 protocols automatically into their own VLANs

Layer 3 routing

  • Basic IP routing: enables automatic routing to the connected VLANs and up to 16 static routes--including one default route--in IP networks

Security

  • Multiple user authentication methods:
    • IEEE 802.1X: industry-standard method of user authentication using an IEEE 802.1X supplicant on the client in conjunction with a RADIUS server

    • Web-based authentication: similar to IEEE 802.1X, it provides a browser-based environment to authenticate clients that do not support the IEEE 802.1X supplicant

    • MAC-based authentication: client is authenticated with the RADIUS server based on the client's MAC address

  • Authentication flexibility:
    • Multiple IEEE 802.1X users per port: provides authentication of up to eight IEEE 802.1X users per port; prevents user "piggybacking" on another user's IEEE 802.1X authentication

    • Concurrent IEEE 802.1X and Web or MAC authentication schemes per port: switch port will accept any of IEEE 802.1X and either Web or MAC authentications

  • Access control lists (ACLs): provide IP Layer 3 filtering based on source/destination IP address/subnet and source/destination TCP/UDP port number

  • Identity-driven ACL: enables implementation of a highly granular and flexible access security policy and VLAN assignment specific to each authenticated network user

  • Dynamic ARP protection: blocks ARP broadcasts from unauthorized hosts, preventing eavesdropping or theft of network data

  • Port security: allows access only to specified MAC addresses, which can be learned or specified by the administrator

  • MAC address lockout: prevents particular configured MAC addresses from connecting to the network

  • Source-port filtering: allows only specified ports to communicate with each other

  • RADIUS/TACACS+: eases switch management security administration by using a password authentication server

  • Secure Shell (SSHv2): encrypts all transmitted data for secure, remote command-line interface (CLI) access over IP networks

  • Port monitoring for network threats: Provides sampled port traffic using sFlow technology to the HP ProCurve Network Immunity Manager application for Network Behavior Anomaly Detection (NBAD) analysis to detect threats and mitigate threats at the port where the threat originated

  • Secure Sockets Layer (SSL): encrypts all HTTP traffic, allowing secure access to the browser-based management GUI in the switch

  • Secure FTP: allows secure file transfer to and from the switch; protects against unwanted file downloads or unauthorized copying of switch configuration file

  • Switch management logon security: can require either RADIUS or TACACS+ authentication for secure switch CLI logon

  • DHCP protection: blocks DHCP packets from unauthorized DHCP servers, preventing denial-of-service attacks

  • STP BPDU port protection: blocks Bridge Protocol Data Units (BPDUs) on ports that do not require BPDUs, preventing forged BPDU attacks

  • STP Root Guard: protects root bridge from malicious attack or configuration mistakes

Convergence

  • IEEE 802.1AB Link Layer Discovery Protocol (LLDP): automated device discovery protocol for easy mapping by network management applications

  • LLDP-MED (Media Endpoint Discovery): a standard extension of LLDP that stores values for parameters such as QoS and VLAN to automatically configure network devices such as IP phones

  • IP multicast snooping and data-driven IGMP: automatically prevents flooding of IP multicast traffic

Quality of Service (QoS)

  • Class of Service (CoS): sets the IEEE 802.1p priority tag based on IP address, IP Type of Service (ToS), L3 protocol, TCP/UDP port number, source port, and DiffServ

  • Layer 4 prioritization: enables prioritization based on TCP/UDP port numbers

  • Traffic prioritization (IEEE 802.1p): allows real-time traffic classification into eight priority levels mapped to four queues

Monitor and diagnostics

  • Port mirroring: enables traffic on a port to be simultaneously sent to a network analyzer for monitoring

Warranty and support

  • ProCurve Lifetime Warranty: for as long as you own the product, with next-business-day advance replacement (available in most countries).

  • Electronic and telephone support: limited electronic and telephone support is available from HP. Refer to the HP Web site at www.procurve.com/support for details on the support provided and the period during which support is available.

  • Software releases: refer to the HP Web site at www.procurve.com/support for details on the software releases provided and the period during which software releases are available.

Models

Standard specifications across all models

Model specifications

HP ProCurve Switch 2610-48
(J9088A)
HP ProCurve Switch 2610-24
(J9085A)
HP ProCurve Switch 2610-24-PWR
(J9087A)
Ports
48 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)

Media Type: Auto-MDIX

Duplex: half or full

1 RJ-45 serial console port

2 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)

Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only

2 open mini-GBIC (SFP) slots

24 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)

Media Type: Auto-MDIX

Duplex: half or full

1 RJ-45 serial console port

2 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)

Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only

2 open mini-GBIC (SFP) slots

24 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)

Media Type: Auto-MDIX

Duplex: half or full

1 RJ-45 serial console port

2 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)

Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only

2 open mini-GBIC (SFP) slots

Physical characteristics
Dimensions 9.3(d) x 17.4(w) x 1.73(h) in. (23.62 x 44.2 x 4.39 cm) (1U height) 9.3(d) x 17.4(w) x 1.73(h) in. (23.62 x 44.2 x 4.39 cm) (1U height) 12.5(d) x 17.4(w) x 1.73(h) in. (31.75 x 44.2 x 4.39 cm) (1U height)
Weight 10.75 lb. (4.88 kg), Fully loaded 5.5 lb. (2.49 kg), Fully loaded 15.05 lb. (6.83 kg), Fully loaded
Memory and processor
Processor MIPS @ 300 MHz, 16 MB flash, 128 MB SDRAM; packet buffer size: 2 MB MIPS @ 300 MHz, 16 MB flash, 128 MB SDRAM; packet buffer size: 1 MB MIPS @ 300 MHz, 16 MB flash, 128 MB SDRAM; packet buffer size: 1 MB
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Performance
100 Mb Latency < 6.2 µs (LIFO) < 4.1 µs (LIFO) < 4.1 µs (LIFO)
1000 Mb Latency < 4.4 µs (LIFO) < 2.9 µs (LIFO) < 2.9 µs (LIFO)
Throughput up to 13.0 million pps up to 9.5 million pps up to 9.5 million pps
Routing/Switching capacity 17.6 Gbps 12.8 Gbps 12.8 Gbps
MAC address table size 8,000 entries 8,000 entries 8,000 entries
Environment
Operating temperature 32¨¬F to 122¨¬F (0¨¬C to 50¨¬C) 32¨¬F to 122¨¬F (0¨¬C to 50¨¬C) 32¨¬F to 122¨¬F (0¨¬C to 50¨¬C)
Operating relative humidity 15% to 95% @ 104¨¬F (40¨¬C), non-condensing 15% to 95% @ 104¨¬F (40¨¬C), non-condensing 15% to 95% @ 104¨¬F (40¨¬C), non-condensing
Non-operating/Storage temperature -40¨¬F to 158¨¬F (-40¨¬C to 70¨¬C) -40¨¬F to 158¨¬F (-40¨¬C to 70¨¬C) -40¨¬F to 158¨¬F (-40¨¬C to 70¨¬C)
Non-operating/Storage relative humidity 15% to 90% @ 149¨¬F (65¨¬C), non-condensing 15% to 90% @ 149¨¬F (65¨¬C), non-condensing 15% to 90% @ 149¨¬F (65¨¬C), non-condensing
Altitude up to 10,000 ft. (3 km) up to 10,000 ft. (3 km) up to 10,000 ft. (3 km)
Acoustic Power: 45 dB, Pressure: 36.2 dB; DIN 45635T.19 per ISO 7779 Power: 0 dB, Pressure: 0 dB No Fan Power: 64 dB, Pressure: 57 dB; DIN 45635T.19 per ISO 7779
Electrical characteristics
Achieved Miercom Certified Green Award
Maximum heat dissipation 285 BTU/hr (300.67 kJ/hr) 142 BTU/hr (149.81 kJ/hr) 410 BTU/hr (432.55 kJ/hr), (switch-only BTU/hr: 410; combined switch + max. PoE devices at 15.4 W: 2281 BTU/hr )
Voltage 100-127 / 200-240 VAC 100-127 / 200-240 VAC 100-127 / 200-240 VAC
Current 1.3 / 0.8 A 0.8 / 0.4 A 7.0 / 3.5 A
Maximum power rating 66 W 41 W 77 W
Frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Notes Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Power consumption: 77 W without PoE; 527 W with PoE.
Safety
CSA 22.2 No. 60950
UL 60950
IEC 60950
EN 60950
CSA 22.2 No. 60950
UL 60950
IEC 60950
EN 60950
CSA 22.2 No. 60950
UL 60950
IEC 60950
EN 60950
HP ProCurve Switch 2610-48-PWR
(J9089A)
HP ProCurve Switch 2610-24/12PWR
(J9086A)
Ports
48 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)

Media Type: Auto-MDIX

Duplex: half or full

1 RJ-45 serial console port

2 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)

Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only

2 open mini-GBIC (SFP) slots

24 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)

Media Type: Auto-MDIX

Duplex: half or full

1 RJ-45 serial console port

2 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)

Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only

2 open mini-GBIC (SFP) slots

Physical characteristics
Dimensions 13.5(d) x 17.4(w) x 1.73(h) in. (34.29 x 44.2 x 4.39 cm) (1U height) 9.3(d) x 17.4(w) x 1.73(h) in. (23.62 x 44.2 x 4.39 cm) (1U height)
Weight 16.7 lb. (7.58 kg), Fully loaded 7.5 lb. (3.4 kg)
Memory and processor
Processor MIPS @ 300 MHz, 16 MB flash, 128 MB SDRAM; packet buffer size: 2 MB MIPS @ 300 MHz, 16 MB flash, 128 MB SDRAM; packet buffer size: 1 MB
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Performance
100 Mb Latency < 6.2 µs (LIFO) < 4.1 µs
1000 Mb Latency < 4.4 µs (LIFO) < 2.9 µs
Throughput up to 13.0 million pps up to 9.5 million pps
Routing/Switching capacity 17.6 Gbps 12.8 Gbps
MAC address table size 8,000 entries 8,000 entries
Environment
Operating temperature 32¨¬F to 122¨¬F (0¨¬C to 50¨¬C) 32¨¬F to 122¨¬F (0¨¬C to 50¨¬C)
Operating relative humidity 15% to 95% @ 104¨¬F (40¨¬C), non-condensing 15% to 95% @ 104¨¬F (40¨¬C), non-condensing
Non-operating/Storage temperature -40¨¬F to 158¨¬F (-40¨¬C to 70¨¬C) -40¨¬F to 158¨¬F (-40¨¬C to 70¨¬C)
Non-operating/Storage relative humidity 15% to 90% @ 149¨¬F (65¨¬C), non-condensing 15% to 90% @ 149¨¬F (65¨¬C), non-condensing
Altitude up to 10,000 ft. (3 km) up to 10,000 ft. (3 km)
Acoustic Power: 63.6 dB, Pressure: 56.6 dB; DIN 45635T.19 per ISO 7779 Power: 46 dB, Pressure: 38.4 dB; DIN 45635T.19 per ISO 7779
Electrical characteristics
Maximum heat dissipation 410 BTU/hr (432.55 kJ/hr), (switch-only BTU/hr: 410; combined switch + max. PoE devices at 15.4 W: 2281 BTU/hr) 181 BTU/hr (190.96 kJ/hr), (switch-only BTU/hr: 181; combined switch + max. PoE devices at 15.4 W: 827 BTU/hr)
Voltage 100-127 / 200-240 VAC 100-127 / 200-240 VAC
Current 7.0 / 3.5 A 2.5 / 1.3 A
Maximum power rating 96 W 62 W
Frequency 50 / 60 Hz 50 / 60 Hz
Notes Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Power consumption: 96 W without PoE; 590 W with PoE.
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Power consumption: 62 W without PoE; 189 W with PoE.
Safety
CSA 22.2 No. 60950
UL 60950
IEC 60950
EN 60950
CSA 22.2 No. 60950
UL 60950
IEC 60950
EN 60950

Standard specifications across all models

Emissions

FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A

Immunity

EN: EN 55024, CISPR 24

ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD

Radiated: IEC 61000-4-3; 3V/m

EFT/Burst: IEC 61000-4-4; 1.0 kV(power line), 0.5kV (signal line)

Surge: IEC 61000-4-5; 1 kV/2 kV AC

Conducted: IEC 61000-4-6; 3V

Power frequency magnetic field: IEC 61000-4-8; 1A/m,50 or 60 Hz

Voltage dips and interruptions: IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods

Harmonics: EN 61000-3-2, IEC 61000-3-2

Flicker: EN 61000-3-3, IEC 61000-3-3

Management

HP ProCurve Manager Plus; HP ProCurve Manager (included); command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)

Standards and protocols

Device management

HTML and telnet management

General protocols

IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1v VLAN classification by Protocol and Port
IEEE 802.1w Rapid Reconfiguration of Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.3af Power over Ethernet
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
RFC 826 ARP
RFC 854 TELNET
RFC 951 BOOTP
RFC 1542 BOOTP Extensions
RFC 2030 Simple Network Time Protocol (SNTP) v4
RFC 2131 DHCP
RFC 3046 DHCP Relay Agent Information Option

IP multicast

RFC 3376 IGMPv3

MIBs

RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 1573 SNMP MIB II
RFC 2021 RMONv2 MIB
RFC 2096 IP Forwarding Table MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2863 The Interfaces Group MIB

Network management

IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
RFC 3164 BSD syslog Protocol
RFC 3176 sFlow
ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
SNMPv1/v2c/v3

Security

IEEE 802.1X Port Based Network Access Control
RFC 1492 TACACS+
Secure Sockets Layer (SSL)
SSHv1/SSHv2 Secure Shell

Notes

When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product ends with the letter "B" or later, e.g., J4858B, J4859C) are required.

Power Supply

 
¡Ú ¹è¼Û±â°£ ¡Ú
ÀÔ±Ý È®ÀÎÈÄ Æò±Õ 3ÀÏ À̳»·Î ¹è¼ÛµË´Ï´Ù. Åä¿äÀÏ/°øÈÞÀÏÀº ¹è¼Û±â°£¿¡ Æ÷ÇÔµÇÁö ¾Ê½À´Ï´Ù.
ÀϹÝÀûÀ¸·Î ÆòÀÏÀº ´çÀÏ ¿ÀÈÄ4½Ã 30ºÐ Àü±îÁö,Åä¿äÀÏÀº ´çÀÏ ¿ÀÈÄ 1½Ã±îÁö ÀÔ±ÝÈ®ÀÎÀÌ µÇ¸é ´ÙÀ½ ³¯ ¹Þ¾Æº¸½Ç ¼ö ÀÖ½À´Ï´Ù.
´Ü, µµ¼­/»ê°£Áö¿ªÀº 2¡­3ÀÏ Á¤µµ Ãß°¡ ¼Ò¿äµË´Ï´Ù.
ºÒ°¡Ç×·ÂÀû(ÀϽÃÇ°Àý, Á¦Á¶»ç »óÇ°¼ö±Þ ¹®Á¦, õÀçÁöº¯ µî)ÀÎ »çÀ¯·Î ¹è¼ÛÀÌ ´Ê¾îÁú¼ö ÀÖ½À´Ï´Ù.

¡Ú ¹è¼ÛÁö¿ª ¡Ú
Àü±¹ (ÀϺÎÁö¿ª Á¦¿Ü)

¡Ú ¹è¼Ûºñ ¡Ú
1¹Ú½º´ç 2500¿ø(Åùè) (µµ¼­ »ê°£Áö¿ªÀº Ãß°¡ºñ¿ë ÀÖÀ»¼ö ÀÖ½À´Ï´Ù.)
ºÎÇdzª Áß·®ÀÌ Å« Á¦Ç°Àº ¹è¼Û ¹æ¹ýÀÌ º¯°æ µÉ ¼ö ÀÖÀ¸¸ç ÀÌ¿¡ µû¸¥ ¿îÀÓºñ°¡ Ãß°¡ µÉ ¼ö ÀÖ½À´Ï´Ù.
¹è¼ÛÀÌ ´Ê¾îÁö´Â °æ¿ì ¹Ì¸® ¿¬¶ôµå¸³´Ï´Ù.
°¢ Á¦Á¶»çÀÇ A/S ±ÔÁ¤¿¡ µû¸¨´Ï´Ù.
Á¦Ç° ±¸¸Å Àμö ÈÄ 7ÀÏ À̳»ÀÇ Á¦Ç°Àº Ãʱ⠺ҷ®¿¡ ÇÑÇØ 1:1 »óÇ° ±³È¯ ¶Ç´Â ȯºÒÀÌ °¡´ÉÇÕ´Ï´Ù.
´Ü, Á¦Ç°ÀÇ ¹Ú½º ¹× ±¸¼º¹°ÀÌ Á¤»ó »óÅ¿¡¼­¸¸ °¡´É ÇÕ´Ï´Ù.
°³ºÀÀ» ¾ÈÇϽŠÁ¦Ç°Áß º¯½É¿¡ ÀÇÇÑ ¹ÝÇ°µµ 7ÀÏ À̳»¿¡¸¸ °¡´ÉÇÕ´Ï´Ù.
Á¦Ç°À» ȯºÒ¹ÞÀ¸½Ã±â À§Çؼ­´Â Á¦Ç°ÀÇ Æ÷Àå»óÅÂ¿Í ³»¿ë¹°ÀÌ ÈѼյÇÁö ¾Ê¾Æ¾ß ÇÏ¸ç ½ºÆ¼Ä¿, Å×ÀÌÇÁ¸¦ ºÙ¿©¼­ Á¦Ç°ÀÇ ¹Ú½º Æ÷ÀåÀÌ ÈѼյǸé ȯºÒÀÌ ºÒ°¡ÇÕ´Ï´Ù.

ÀüÈ­¿¬¶ôÀ» ¸ÕÀú ÁÖ½Ã¸é ½Å¼ÓÇÑ Ã³¸®°¡ µË´Ï´Ù.
 
 
À̸§ : ÷ºÎ : ÆÄÀÏ÷ºÎ
³»¿ë :
ÆòÁ¡
°í°´Æò°¡ : ÆòÁ¡ ¡Ú¡Ú¡Ú¡Ú¡Ú  
 
 
 
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Á¶È¸
 
 
 
»óÈ£¸í : (ÁÖ)¾ÆÀÌÇǵ帲 »ç¾÷ÀÚµî·Ï¹øÈ£ : 581-86-00309 581-86-00309 Åë½ÅÆǸž÷½Å°í¹øÈ£ : Á¦2016-¼­¿ï¿ë»ê-00683È£
[ÀÌ¿ë¾à°ü] [°³ÀÎÁ¤º¸ Ãë±Þ¹æħ] °³ÀÎÁ¤º¸´ã´çÀÚ : ¾È±â¼¼ ´ëÇ¥ : ¾È±â¼¼
»ç¾÷Àå¼ÒÀçÁö : ¼­¿ï ¿ë»ê±¸ »õâ·Î 181 (ÇÑ°­·Î2°¡, ¼±Àλó°¡22µ¿ 1046È£,1047È£,1048È£)
Copyright ¨Ï ·£°ø»ç All Rights Reserved. TEL : 02-707-3385, FAX : 02-707-3368